1.
J. Bras. Patol. Med. Lab. (Online) ; 56: e0932020, 2020. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1090756

ABSTRACT

ABSTRACT Introduction: The oral glucose tolerance test (OGTT) is an important test for diagnosis of diabetes mellitus (DM) that needs criteria to be requested and analytical performance evaluation. Objectives: Determine the prevalence of unnecessary OGTT requests and analyze patients' suitability criteria for glucose load. Method: Cross-sectional, descriptive and analytical study conducted with 554 patients who had OGTT requested from January to April 2018. Data from laboratory tests were collected through Complab Advanced version 6.9.6 system, organized into a Microsoft® Excel table and analyzed using Epi InfoTM, version 7.2.1.0. The accuracy of the glucometer paired analysis was performed by determinations of Student's t test, using SPSS version of IBM 21TM. Patients with a previous diagnosis of DM and/or who showed OGTT request as a screening test along with blood glucose or glycated hemoglobin were classified as unnecessary requests. Results: Among the studied patients, 17% (94) had unnecessary OGTT requests, 53 (53.4%) patients had blood glucose ≥ 140 mg/dl and previous DM and/or OGTT used as screening; 41 (43.6 %) patients with capillary blood glucose < 140 mg/dl, but with a diagnosis of DM. The glucometer proved to be accurate with a high correlation (r 2 = 0.97, p < 0.0001) with serum glucose. Approaches during screening and capillary blood glucose prevented unnecessary exposure to glucose overload in 67% (63) of the patients. Conclusion: The high prevalence of unnecessary OGTT requests underscores the need of criteria for OGTT requesting and the standardization of procedures for screening in the exam.


RESUMEN Introducción: La prueba de tolerancia a la glucosa oral (PTGO) es un importante examen para diagnóstico de la diabetes mellitus (DM) que requiere criterios de solicitud y estandarización en su consecución. Objetivos: Establecer la prevalencia de solicitudes innecesarias de PTGO y analizar los criterios de aptitud del paciente para una sobrecarga de glucosa. Método: Estudio de corte transversal, descriptivo y analítico, llevado a cabo con 554 pacientes que tuvieron PTGO solicitado entre enero y abril de 2018. Datos de las pruebas de laboratorio fueron recolectados con el sistema Complab Advanced versión 6.9.6, tabulados en Microsoft® Excel y analizados en Epi InfoTM, versión 7.2.1.0. La precisión del glucómetro fue medida por análisis pareado de las determinaciones en la prueba t de Student, mediante el IBM SPSS® versión 21TM. Pacientes con diagnóstico previo de DM y/o que presentaron solicitud de PTGO como prueba de cribado junto con glucemia o hemoglobina glucosilada fueron clasificados como peticiones innecesarias. Resultados: Entre los pacientes investigados, el 17% (94) tuvieron peticiones innecesarias de PTGO: 53 (53,4%) con glucemia capilar ≥ 140 mg/dl y DM previo y/o PTGO usado como cribado; 41 (43,6%) con glucemia capilar < 140 mg/dl, pero con diagnóstico de DM. El glucómetro se mostró preciso, con alta correlación (r2 = 0,97, p < 0,0001) con la glucemia sérica. Los enfoques durante el cribado y la glucemia capilar evitaron la exposición innecesaria a la sobrecarga de glucosa en el 67% (63) de los pacientes. Conclusión: El alta prevalencia de peticiones innecesarias de PTGO destaca la necesidad de criterios para la solicitud de la PTGO, así como la estandarización de procedimientos para cribado en la consecución de esa prueba.


RESUMO Introdução: O teste oral de tolerância à glicose (TOTG) é um importante exame para diagnóstico do diabetes mellitus (DM) que necessita de critérios para solicitação e padronização em sua realização. Objetivos: Determinar a prevalência de solicitações desnecessárias de TOTG e analisar os critérios de aptidão do paciente para sobrecarga glicêmica. Método: Estudo de corte transversal, descritivo e analítico, realizado com 554 pacientes que tiveram TOTG solicitado entre janeiro e abril de 2018. Dados dos exames laboratoriais foram coletados utilizando o sistema Complab Advanced versão 6.9.6, tabulados no Microsoft® Excel e analisados no Epi InfoTM, versão 7.2.1.0. A acurácia do glicosímetro foi medida por análise pareada das determinações em teste t de Student, por meio do IBM SPSS® versão 21TM. Pacientes com diagnóstico prévio de DM e/ou que apresentaram solicitação de TOTG como teste de triagem junto com glicemia ou hemoglobina glicada foram classificados como solicitações desnecessárias. Resultados: Dos pacientes estudados, 17% (94) tiveram solicitações desnecessárias de TOTG: 53 (53,4%) com glicemia capilar ≥ 140 mg/dl e DM prévio e/ou TOTG usado como triagem; 41 (43,6%) com glicemia capilar < 140 mg/dl, mas com diagnóstico de DM. O glicosímetro mostrou-se preciso, com elevada correlação (r 2 = 0,97, p < 0,0001) com a glicemia sérica. As abordagens durante a triagem e a glicemia capilar evitaram a exposição desnecessária à sobrecarga de glicose em 67% (63) dos pacientes. Conclusão: A alta prevalência de solicitações desnecessárias de TOTG ressalta a necessidade de critérios para solicitação do TOTG, bem como a padronização de procedimentos para triagem na realização desse exame.

2.
J. Bras. Patol. Med. Lab. (Online) ; 56: e1432020, 2020. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1090760

ABSTRACT

ABSTRACT Introduction: Laboratory tests are intended to provide information necessary to clarify diagnoses or specific situations that cannot be elucidated by other means. Laboratory analyses are subject to several interferences. Even healthy individuals could suffer variations in laboratory tests due to biological factors, which may lead to misinterpretation of the results. Objective: Assess the pre-analytical variables in patients' laboratory tests at the Vitória da Conquista Central Laboratory, Bahia, Brazil. Material and method: This is a cross-sectional study with a descriptive approach and the use of a questionnaire as a research instrument. Data were collected through individual interviews, carried out at the laboratory. Results: The sample consisted of 425 patients, with female predominance (76.5%). Regarding patient instructions for laboratory tests, 94.6% had not been given any previous guidance, and 68.5% used some kind of medication, which could produce alterations in the exams. The use of the antihypertensive agents captopril, enalapril, hydrochlorothiazide or propranolol was associated with increased serum urea [odds ratio (OR) = 7.2, confidence interval (CI) = 95%, 1.87-27.58; p = 0.002], and smoking was associated with increased red blood cells count (OR = 3.7, CI = 95%, 0.86-15.75; p = 0.02). Conclusion: The findings indicate that pre-analytical variables remain an important focus for attention to the clinical laboratory. The correct data collection of patients' conditions is critical to support the post-analytical phase with useful information for the production of reliable exams and serve as a useful interpretation to diagnosis.


RESUMEN Introducción: Las pruebas de laboratorio tienen como objetivo proporcionar información necesaria a la aclaración de diagnósticos o situaciones específicas que no se pueden esclarecer por otros modos. Los análisis de laboratorio están sujetos a diversos interferentes. Incluso individuos sanos pueden presentar variaciones en las pruebas derivadas de factores que pueden crear equivocaciones en la interpretación de los resultados. Objetivo: Evaluar la influencia de variables preanalíticas en pruebas de laboratorio de pacientes atendidos en el Laboratório Central de Vitória da Conquista, Bahía, Brasil. Material y método: Estudio transversal con enfoque descriptivo y empleo de cuestionario como herramienta de investigación. Los datos fueron recogidos mediante entrevistas individuales, realizadas en el establecimiento investigado. Resultados: La muestra se compuso por 425 pacientes, con predominio de mujeres (76,5%). En cuanto a instrucciones para realización de las pruebas, el 94,6% de los pacientes no recibieron ningún tipo de orientación previa y el 68,5% utilizaban algún tipo de medicamento que puede producir alteraciones en pruebas. El uso de los antihipertensivos captopril, enalapril, hidroclorotiazida o propranolol estuvo asociado con el aumento de la urea sérica [oportunidad relativa (OR) = 7,2; intervalo de confianza (IC) = 95%, 1,87-27,58; p = 0,002]. El tabaquismo se ha asociado al aumento de eritrocitos (OR = 3,7; IC = 95%, 0,86-15,75; p = 0,02). Conclusión: Los hallazgos clínicos indican que variables preanalíticas son importante causa de atención para el laboratorio clínico. La correcta recogida de datos acerca de las condiciones de los pacientes es esencial para instrumentar la fase postanalítica con información relevante para la realización de pruebas fiables y que sean útiles para el proceso del diagnóstico.


RESUMO Introdução: Os exames laboratoriais têm como objetivo fornecer informações necessárias para o esclarecimento de diagnósticos ou situações específicas não passíveis de serem elucidadas por outros meios. As análises laboratoriais estão sujeitas a diversos interferentes. Mesmo indivíduos saudáveis podem apresentar variações nos exames decorrentes de fatores que podem gerar equívocos na interpretação dos resultados. Objetivos: Avaliar a influência de variáveis pré-analíticas em exames laboratoriais de pacientes atendidos no Laboratório Central do município de Vitória da Conquista, Bahia, Brasil. Material e método: Trata-se de um corte transversal com abordagem descritiva e utilização de questionário como instrumento de pesquisa. Os dados foram coletados por meio de entrevistas individuais, realizadas na instituição pesquisada. Resultados: A amostra foi composta por 425 pacientes, com predomínio de indivíduos do sexo feminino (76,5%). No que se refere a instruções para realização dos exames laboratoriais, 94,6% dos pacientes não receberam nenhum tipo de orientação prévia e 68,5% utilizavam algum tipo de medicamento que pode produzir alterações em exames. O uso dos anti-hipertensivos captopril, enalapril, hidroclorotiazida ou propranolol esteve associado ao aumento da ureia sérica [odds ratio (OR) = 7,2; intervalo de confiança (IC) = 95%, 1,87-27,58; p = 0,002]. O tabagismo associou-se ao aumento de eritrócitos (OR = 3,7; IC = 95%, 0,86-15,75; p = 0,02). Conclusão: Os achados indicam que variáveis pré-analíticas são importante fonte de atenção para o laboratório clínico. A correta coleta de dados acerca das condições dos pacientes é fundamental para instrumentar a fase pós-analítica com informações relevantes para a produção de exames fidedignos e que sejam úteis ao processo do diagnóstico.

3.
J. Bras. Patol. Med. Lab. (Online) ; 54(4): 220-226, July-Aug. 2018. tab, graf
Article in English | LILACS | ID: biblio-954405

ABSTRACT

ABSTRACT Introduction: Recommendations in the literature and publications of scientific societies have proposed classification systems and levels to report blood cell changes in the complete blood count (CBC). Aiming to standardize the results released in the clinical laboratory, the standardization in hematoscopy is an important action within the quality assurance, contributing for diagnosis and appropriate follow-up of patients. Objective: To verify the adequacy of the classification criteria of the blood smear changes adopted by the laboratory professionals at the General Hospital of Vitória da Conquista, Bahia, Brazil. Material and method: In the 12-week period, 159 slides of CBC were selected from 53 patients from the four intensive care units (ICUs) at the hospital, three slides per patient. The readings of the slides were performed by the analysts on duty and by two other quality analysts-control who used the criteria standardized by Palmer (2015), all analyses were blind and independent. The results were compared using the Cohen's kappa agreement tests between the analysts-control and between the quality control analysts and the analysts on duty. Results: For the analyzed parameters, there was moderate to excellent agreement among the quality analysts-control, and when they were compared to the analysts on duty, there was a slight to substantial agreement. Discussion: The lowest agreement occurred in the expression of poikilocytosis and lymphocytic atypia, which are not detected by the hemocytometer, and the analyst's technical capacity is required. Conclusion: The study evidenced the need of standardization of the criteria for hematoscopy used by analysts to obtain reproducible results that reflect quality and reliability by the prescribing physician. Therefore, it is necessary to invest in training the professionals involved in revision of blood smear slides.


RESUMO Introdução: Recomendações em literatura e publicações de sociedades científicas têm proposto sistemas e níveis de classificação para comunicar alterações hematoscópicas no hemograma. Visando a uniformização dos resultados liberados no laboratório clínico, a padronização em hematoscopia apresenta-se como uma ação importante dentro da garantia da qualidade, contribuindo de modo coerente para diagnóstico acurado e adequado acompanhamento de pacientes. Objetivo: Verificar a adequação dos critérios de classificação das alterações hematocópicas adotados pelos profissionais do laboratório do Hospital Geral de Vitória da Conquista, Bahia, Brasil. Material e método: No período de 12 semanas, foram selecionadas 159 lâminas de hemogramas provenientes de 53 pacientes de quatro unidades de terapia intensiva (UTIs) do hospital, sendo três lâminas por paciente. Foram realizadas leituras das lâminas pelo plantonista do laboratório e por duas analistas-controle que utilizaram critérios padronizados por Palmer (2015), sendo todas as análises cegas e independentes. Os resultados foram comparados por meio do teste de concordância kappa de Cohen entre as analistas-controle e os plantonistas. Resultados: Para os parâmetros analisados, observou-se entre as analistas-controle concordância moderada a excelente e, quando comparadas com os plantonistas, verificou-se concordância ligeira a substancial. Discussão: A menor concordância ocorreu na expressão de poiquilocitose e atipia linfocitária, que não são detectadas pelos hemocitômetros, sendo necessária a capacidade técnica do analista. Conclusão: O estudo evidenciou uma necessidade de padronização dos critérios para hematoscopia usados pelos analistas para obtenção de resultados reprodutíveis que espelhem qualidade e confiabilidade por parte dos prescritores. Para tanto, é necessário investimento em treinamentos dos profissionais envolvidos na revisão de lâminas hematológicas.

4.
J. Bras. Patol. Med. Lab. (Online) ; 53(6): 382-387, Nov.-Dec. 2017. tab, graf
Article in English | LILACS | ID: biblio-893584

ABSTRACT

ABSTRACT Introduction: Pseudothrombocytopenia is an important source of pre-analytical problems in clinical laboratory; therefore it must be correctly evaluated. Low spurious platelet counts can lead to misdiagnosis. Objective: This study aims to study the resolution of pseudothrombocytopenia in the laboratory routine of clinical laboratory by standardizing the use of vortexer. Methods: This is a cross-sectional, analytical, quantitative study based on experimental approach, involving 45 pseudothrombocytopenia samples divided into three groups and submitted to vortexing for 1, 2 and 3 minutes. Results: During the study, 28,435 blood counts were performed, and 56 (0.196%) of these samples confirmed platelet aggregates. The 2 and 3 minute times normalized the platelet count (greater than 150,000/µl) in two thirds of the samples tested. Platelets, hemolysis index, platelet distribution width (PDW) and mean platelet volume (MPV) presented statistically significant mean difference (MD) (p < 0.05) after vortexing at all times. Conclusion: The 2 and 3-minute times were the most effective in the resolution of pseudothrombocytopenia, however, the 2 minutes time should be preferred because it produced fewer effects on the erythrocyte membrane.


RESUMO Introdução: A pseudotrombocitopenia constitui importante fonte de problemas pré-analíticos no laboratório clínico, por isso deve ser corretamente avaliada. Baixas contagens de plaquetas espúrias podem levar a suspeitas diagnósticas equivocadas. Objetivo: Este estudo se propôs a estudar a resolução da pseudotrombocitopenia na rotina de laboratório de análises clínicas pela padronização do uso de vortex. Métodos: Trata-se de um estudo transversal analítico e quantitativo, apresentando-se dentro de uma abordagem de cunho experimental, o qual envolveu 45 amostras pseudotrombocitopênicas divididas em três grupos e submetidas a agitação com vortex nos tempos de 1, 2 e 3 minutos. Resultados: Durante a realização do estudo, foram realizados 28.435 hemogramas, sendo 56 (0,196%) amostras confirmadas com a presença de agregados plaquetários. Os tempos de 2 e 3 minutos normalizaram a contagem de plaquetas (maior que 150.000/µl), em dois terços das amostras testadas. Plaquetas, índice de hemólise, amplitude de distribuição das plaquetas (PDW) e volume plaquetário médio (VPM) apresentaram diferença de média estatisticamente significativa (p < 0,05) após o tratamento com vortex em todos os tempos testados. Conclusão: Os tempos de 2 e 3 minutos foram os mais eficazes na resolução da pseudotrombociopenia, contudo, o tempo de 2 minutos deve ser utilizado por ter produzido menores efeitos sobre a membrana eritrocitária.

5.
Braz. j. infect. dis ; 21(4): 464-467, July-Aug. 2017. tab
Article in English | LILACS | ID: biblio-1039197

ABSTRACT

Abstract Nasal colonization with methicillin-resistant Staphylococcus aureus (MRSA) have increasingly been reported in healthy communities. This study aimed to assess the rate of S. aureus in general and MRSA in particular from nasal secretion of children in daycare centers in Vitória da Conquista, Brazil. The isolates were identified based on morphology, biochemical tests and by PCR. Detection of virulence genes, biofilm production, and susceptibility test by disk diffusion agar were performed. MRSA isolates were characterized by spa, SCCmec, and multilocus sequence typing (MLST). S. aureus were recovered from 70 (47.3%) of 148 children. Among the 11 MRSA strains (15.7%), two SCCmec types (IV and V) were detected. MLST identified four STs related to three clonal complexes (CC): 5, 45, and 398. Four spa types were found circulating in this setting. Resistance of S. aureus isolates to ampicillin, erythromycin, ciprofloxacin, clindamycin, and tetracycline was 80%, 32.8%, 7.1%, 7.1% and 4.3%, respectively. One isolate presented intermediate resistance to vancomycin detected by Etest methodology. All strains were biofilm producers. The virulence genes seb, sec, spa, and pvl were detected in some isolates. This study revealed a high rate of children carrying MRSA among healthy attendees in daycare centers in Vitória da Conquista, Brazil.


Subject(s)
Humans , Male , Female , Infant , Child, Preschool , Child , Staphylococcal Infections/microbiology , Child Day Care Centers , Nose/microbiology , Community-Acquired Infections/microbiology , Biofilms/growth & development , Virulence Factors , Disk Diffusion Antimicrobial Tests , Methicillin-Resistant Staphylococcus aureus/isolation & purification , Methicillin-Resistant Staphylococcus aureus/drug effects , Methicillin-Resistant Staphylococcus aureus/pathogenicity , Genotype , Anti-Bacterial Agents/pharmacology
6.
J. Bras. Patol. Med. Lab. (Online) ; 53(4): 233-239, July-Aug. 2017. tab
Article in English | LILACS | ID: biblio-893562

ABSTRACT

ABSTRACT Introduction: Test repetitions are an age-old practice common to clinical laboratories used primarily for confirmation of results. However, knowing the history of patients, the repetitions become avoidable. They impair the time to release results, increase input consumption, and cost of services. Objectives: to evaluate the difference between the results of the laboratory tests repetitions and the expenditure generated by each additional test. Materials and methods: Data from repeated tests from September to November 2015 were used in the laboratory of a public hospital in the state of Bahia, Brazil. The classification of necessary or unnecessary repetition of these tests was performed according to international criteria, with subsequent cost estimation. Results: A total of 1,350 samples were analyzed, with a total of 1,429 repetitions; 1,162 (81.31%) were classified as unnecessary repetitions, generating an additional cost of R$ 1,198.00 to the service. The repetitions that made up the study generated a cost of R$ 1,488.61, the expense should be only R$ 290.61, an increase of 80.47%, an estimated annual impact of R$ 4,792.00. In addition to the impact on cost, the impact on turnaround time was evident, which consequently affects the speed in patient care. Conclusion: It was observed that most of the repetitions performed in the laboratory were classified as unnecessary when evaluated by the criteria used. These repetitions generated a potentially avoidable laboratory cost increase, negatively impacting the time to release the results.


RESUMO Introdução: A repetição de exames é uma prática antiga comum aos laboratórios clínicos, usada basicamente para confirmação de resultados. No entanto, ao conhecer a história dos pacientes, as repetições tornam-se evitáveis. Elas prejudicam o tempo de liberação de resultados, aumentam consumo de insumos e geram custo aos serviços. Objetivos: Avaliar a diferença entre os resultados das repetições de exames laboratoriais e o dispêndio gerado por cada teste adicional. Materiais e métodos: Foram utilizados dados de exames repetidos de setembro a novembro de 2015 no laboratório de um hospital público do estado da Bahia, Brasil. Procedeu-se a classificação de repetição necessária ou desnecessária desses exames seguindo critérios internacionais, com posterior estimativa de custo. Resultados: Um total de 1.350 amostras foram analisadas, com 1.429 repetições ao todo; 1.162 (81,31%) foram classificadas como repetições desnecessárias, gerando um custo adicional ao serviço no valor de R$ 1.198,00. As repetições que compuseram o estudo geraram um custo de R$ 1.488,61, o gasto deveria ser de apenas R$ 290,61, ou seja, um acréscimo de 80,47%, um impacto anual estimado em R$ 4.792,00. Além do impacto no custo, ficou evidente o impacto no tempo de resposta, o que consequentemente afeta a celeridade na assistência aos pacientes. Conclusão: Observou-se que a maioria das repetições realizadas no laboratório foi classificada como desnecessária quando avaliada pelos critérios utilizados. Essas repetições geraram ao serviço um acréscimo de custo laboratorial potencialmente evitável, impactando negativamente no tempo para liberação dos resultados.

7.
J. bras. patol. med. lab ; 52(2): 103-106, Mar.-Apr. 2016. tab, graf
Article in English | LILACS | ID: lil-782035

ABSTRACT

ABSTRACT Lipemia can be characterized by serum turbidity caused by accumulation of lipoproteins and is a major cause of interference in laboratory analyzes. Hypertriglyceridemia (HTG) is the third most common cause of acute pancreatitis (AP). Diagnosis and laboratory monitoring of AP associated with HTG are hampered by the intense lipemia associated. This case report proposes an approach to laboratory interference caused by HTG in patient diagnosed with AP and actions target at achieving reliable laboratory tests, free from interference and useful in clinical decision making.


RESUMO A lipemia pode caracterizar-se por turvação no soro provocada por acúmulo de lipoproteínas e constitui importante causa de interferência em análises laboratoriais. A hipertrigliceridemia (HTG) é a terceira causa mais comum de pancreatite aguda (PA). O diagnóstico e o acompanhamento laboratorial de PA associada à HTG são dificultados pela intensa lipemia associada. Este relato de caso propõe uma abordagem sobre as interferências laboratoriais causadas pela HTG em paciente diagnosticado com PA e as ações direcionadas para realização de exames laboratoriais confiáveis, isentos de interferência e úteis na tomada de decisões clínicas.